Cardinal Health AirLife Infant Ventilator Support System Pole Clamp, NEW Battery

$ 115.63

Availability: 100 in stock
  • Brand: Cardinal Health
  • MPN: 006900
  • Refund will be given as: Money Back
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Restocking Fee: No
  • Condition: This device is in good cosmetic condition. I have two of these available and just replaced the batteries in both of them. This listing is for one AirLife nCPAP ventilator system. Ready to use and the patient circuits and tubing are found easily online. Guaranteed not to be DOA
  • Model: AirLife Ventilator System NEW Battery

    Description

    This device is in good cosmetic and excellent tested working condition. I have two of these available and I purchased new batteries and installed them in both units. This listing is for one AirLife nCPAP system. Ready to use and the patient circuits and tubing are found easily online. Guaranteed not to be DOA! Some of the features include: NCPAP – continuous positive airway pressure based on clinician set pressure. Breath rate monitoring/alarm can be activated in this mode. BiPhasic – time triggered pressure assists are delivered based on clinician set Time-High, rate and pressure criteria. Breath rate monitoring/alarm can be activated in this mode. BiPhasic tr* – patient triggered pressure assists delivered based on clinician set Time-High and pressure criteria. Breath rate monitoring/alarm and Apnea backup breaths are automatically active in this mode. Patented Infant Flow® or AirLifeT M Infant nCPAP System Generator - The Infant Flow® Generator is a fluidic device for the generation of consistent infant nasal CPAP with a low work of breathing compared to other devices(1). Fully integrated alarm package – Supply gases failure, High Patient Pressure, Low patient pressure, high and low delivered Oxygen concentration, change from AC to DC power source, low and flat battery charge status and Low breath rate/apnea alarm. Battery Backup – Up to 2 hours of battery backup allows for intra-hospital transport. Clear indicators are provided for power supply in use (AC or DC), and battery charge level. Screen Lock – After 120 seconds of no screen inputs, the screen changes to the Locked Screen to prevent inadvertent changes. Upon activation of a high priority alarm the screen changes to an unlocked state to allow access to controls.
    Cardinal Health AirLife Infant Ventilator Support System Pole Clamp, NEW Battery
    Cardinal Health AirLife Infant Ventilator Support System Pole Clamp, NEW Battery
    Click images to enlarge
    Description
    Pinkmedical Sales
    ~ Deborah Godlevsky ~ Call or Text:
    5207090315
    Description
    This device is in good cosmetic and excellent tested working condition. I have two of these available and I purchased new batteries and installed them in both units. This listing is for one AirLife nCPAP system. Ready to use and the patient circuits and tubing are found easily online. Guaranteed not to be DOA!
    Some of the features include:
    NCPAP – continuous positive airway pressure based on clinician set pressure. Breath rate monitoring/alarm can be activated in this mode.
    BiPhasic – time triggered pressure assists are delivered based on clinician set Time-High, rate and pressure criteria. Breath rate monitoring/alarm can be activated in this mode.
    BiPhasic tr* – patient triggered pressure assists delivered based on clinician set Time-High and pressure criteria. Breath rate monitoring/alarm and Apnea backup breaths are automatically active in this mode.
    Patented Infant Flow® or AirLifeT M Infant nCPAP System Generator - The Infant Flow® Generator is a fluidic device for the generation of consistent infant nasal CPAP with a low work of breathing compared to other devices(1).
    Fully integrated alarm package – Supply gases failure, High Patient Pressure, Low patient pressure, high and low delivered Oxygen concentration, change from AC to DC power source, low and flat battery charge status and Low breath rate/apnea alarm.
    Battery Backup – Up to 2 hours of battery backup allows for intra-hospital transport. Clear indicators are provided for power supply in use (AC or DC), and battery charge level.
    Screen Lock – After 120 seconds of no screen inputs, the screen changes to the Locked Screen to prevent inadvertent changes. Upon activation of a high priority alarm the screen changes to an unlocked state to allow access to controls.
    Specifics
    Cardinal Health AirLife nCPAP System
    Catalog No - 006900
    Serial No - 1008 DL300 , 1008 DL301
    Modes:
    • NCPAP
    • NCPAP with breath rate monitoring and low rate alarm
    • BiPhasic (time triggered)
    • BiPhasic (time triggered) with breath rate monitoring and low rate alarm
    • BiPhasic tr (patient triggered) with breath rate monitoring, low breath rate alarm and apnea back up (Comprehensive models only)
    Controls:
    • Time High (T-High) – 0.1 – 3.0 seconds
    • Rate (R) 1-120 (Non-U.S. Configuration Parameters) 1-54 (U.S. Configuration Parameters)
    • Apnea Interval • (Tapnea) – 10-30 seconds, 5 second intervals (Non-U.S. Configuration Parameters)
    • (TLBR) – 10-30 seconds; 5 second intervals (U.S. Configuration Parameters)
    • NCPAP / Pres Low flow meter – 0-15 L/min, accuracy ± 15% of selected output
    • Pres High flow meter – 0-5 L/min, accuracy ± 15% of selected output
    • Manual Breath – X 1 • %O2 – 21 -100%
    Monitors:
    • CPAP
    • PEEP
    • MAP
    • PIP
    • %O2
    • I:E ratio
    • Spontaneous rate (Rsp)
    • Battery charge level
    Alarms:
    • High airway pressure – 3 cmH2O above measured airway pressure
    • Airway over-pressure limit alarm
    • maximum 11 cmH2O in NCPAP and time triggered BiPhasic mode
    • maximum 15 cmH2O in patient triggered BiPhasic tr mode
    • Low airway pressure – 2 cmH2O below measured airway pressure or 1.5 cmH2O if otherwise would be zero
    • High and Low delivered Oxygen concentration ±5% of setting. Minimum and maximum delivered FiO2 is 18 and 104% respectively.
    • Low breath rate alarm
    • Low battery charge level
    • Flat battery
    • Input gases failure
    • Alarm volume (electronic alarms) 70 dBa at 1 meter
    Pneumatic Supply:
    • Patient Gas Outlet: 15 mm standard taper fitting
    • Patient Pressure Input: 4.5 mm Luer taper fitting
    • Gas Supply: Nominal 4 bar or 60 psi, clean, dry medical air and oxygen
    • Range: 40.61 to 87 PSI; Maximum differential pressure 29 PSI
    • Manometer: Range 0 to + 20 cmH2O, accuracy, ± 2% of span
    • Gas Connections: Standard DISS, NIST or Air Liquide connectors
    Electrical Supply:
    • Input Voltage: 100-230 VAC
    • Input Frequency: 50/60 Hz
    • Power Consumption: 50 VA maximum
    • Fuse Rating For 220 V nominal operation: “T” Type 2.5 A at 250 V
    • Device Housing Protection rating level: IPX1
    • Battery Working Time: 2 hours (from fully charged state)
    • Battery Charging Time: max. 16 hours

    Manufacturer's Description
    Infant Flow® SiPAP™ provides a non-invasive form of respiratory support designed for infants in hospital environments such as Neonatal and Pediatric Intensive Care Units. It can also be used when transporting these patients within the hospital environment.
    Infant Flow® SiPAP™ is currently available in a Plus or Comprehensive* configuration. The Plus configuration provides NCPAP and time triggered BiPhasic modes with and without breath rate monitoring. The Comprehensive* configuration offers these features plus a patient triggered BiPhasic mode with apnea backup breaths. The Infant Flow® SiPAP™ comes standard in all configurations with an LCD touch screen display, pressure time waveform graphics, integrated patient monitoring, alarms for high and low pressure and FiO2 and up to 2 hours of backup battery power.
    As a result of the unique, patented design, the Infant Flow® or AirLifeTM Infant nCPAP System Generator has been proven to provide the most stable CPAP at the lowest work of breathing for patients compared to other devices (1). The outstanding performance of the Infant Flow® Generator is irrespective of patient demand or expiratory flows. This system has been designed and tested to perform optimally when used only with accessories available from CareFusion. These accessories include circuits and generators, prong and mask patient interfaces and bonnets.
    Condition & Testing
    This nCPAP system is in great cosmetic and excellent working condition with normal signs of wear from previous use. Powers on without incident then immediatley alarms to notify you there is no patient circuit or tubing hooked up to unit. Brand new battery. Silence alarm is responding to prompts. No further testing could be done.
    Age
    Unknown
    Dimensions
    Overall - 8.75" wide x 8.5" deep x 6.5" tall
    Warranty
    I stand behind everything I sell and for 30 days I guarantee this
    Cardinal Health AirLife nCPAP
    is exact to the description and pictures I have provided here or return it for a refund
    Shipping
    Weight before packing is
    11 lbs
    for everything pictured
    All buyers may use the shipping calculator
    Pickup is always welcome from our warehouse in Coolidge Az 85128 (40 miles south of Phoenix Az near I-10)
    If the ebay shipping calculator wont give you a shipping cost you must contact me for a shipping quote.
    "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."
    Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment.. The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer. There are no warranties which extend beyond the description on the face hereof. This item has been cleaned and handled in accordance with the manufacturer's instructions.
    .
    Godlevsky Enterprises LLC, Deborah Godlevsky,
    Coolidge Arizona,
    Used equipment sales,
    5207090315
    Images sell!
    Get Supersized Images & Free Image Hosting
    Create your brand with Auctiva's
    Customizable Templates.
    Attention Sellers - Get Templates
    Image Hosting, Scheduling at Auctiva.com.
    Track Page Views With
    Auctiva's FREE Counter